
R448A
25LB Net Weight Cylinder
This factory-sealed R448A refrigerant cylinder is designed for compatible commercial refrigeration, supermarket cooling, and low-temperature refrigeration systems that require R448A. It is suitable for trained HVAC technicians, refrigeration contractors, and maintenance teams working on compatible cooling equipment.
R448A quick specifications
R448A is an HFO/HFC refrigerant blend commonly used in compatible low-temperature and medium-temperature commercial refrigeration systems. This product should only be used in equipment that specifically requires R448A refrigerant.
Use only in systems whose manufacturer documentation identifies R448A as the required refrigerant. R448A must never be mixed with another refrigerant or used as a substitute without manufacturer approval.
Sealed and clearly identified
The steel service cylinder contains 25 lb / 11.3 kg net weight of R448A refrigerant and is supplied with a sealed valve for professional handling.
- One sealed R448A refrigerant cylinder
- 25 lb / 11.3 kg refrigerant net weight
- Approx. 16.5 inches high and 9.8 inches wide
- Non-refillable professional service cylinder
Where R448A is commonly used
R448A may be used to service compatible low-temperature and medium-temperature refrigeration equipment designed for R448A operating requirements. It should only be used when the equipment label identifies R448A as the required refrigerant.
Commercial Refrigeration
Reach-in coolers, walk-in boxes, refrigerated cases and food storage systems.
Supermarket Systems
Low-temperature and medium-temperature refrigeration equipment used in retail cooling.
Retrofit Service Work
Properly evaluated systems replacing R404A, R507, or R22 in compatible applications.
Made for certified technicians
R448A service must be performed by an appropriately certified technician using approved recovery, charging, leak-check and refrigeration service procedures.
Follow the cylinder label, current safety data sheet, equipment manufacturer instructions and all applicable federal, state and local requirements.
- Verify R448A on the equipment nameplate before use
- Section 608 certification is required for stationary equipment
- Recover refrigerant—never knowingly vent refrigerant
- Never mix R448A with another refrigerant
R448A Product FAQs
Clear answers about R448A compatibility, EPA certification, shipping, cylinder weight, refrigeration service, storage and delivery concerns.
Yes. This R448A refrigerant is supplied in a factory-sealed service cylinder. The original seal should remain intact until the cylinder is opened by a trained technician for approved service use.
Check the equipment nameplate, service manual and manufacturer specifications. Use R448A only when the commercial refrigeration equipment is specifically identified for R448A operating requirements.
R448A for stationary air-conditioning and refrigeration equipment is subject to EPA Section 608 sales restrictions. Eligible buyers generally include Section 608-certified technicians, businesses that employ a properly certified technician, and qualified resellers.
Velotrex may request certification, employer authorization or resale documentation before processing an order.
Yes, R448A is commonly used in compatible low-temperature and medium-temperature commercial refrigeration equipment such as freezers, cold rooms, refrigerated cases and food-service cooling systems.
Always confirm the equipment label and service documentation before purchasing. Some applications may reference R448A as a replacement option for R404A, R507A, or R22, but any replacement or retrofit work must be evaluated by a qualified technician.
Orders are normally processed within one business day. Standard delivery is generally estimated at 2–5 business days after carrier pickup. Weekend and public-holiday orders are processed on the next business day.
Multiple cylinders may ship separately. Delivery estimates can be affected by carrier routing, weather, hazardous-material requirements and address restrictions.
A carrier label may display estimated, preset, dimensional or billing weight. This can differ from the product’s 24 lb / 10.9 kg refrigerant net weight because the cylinder and shipping packaging add weight.
If you have a concern after delivery, keep the cylinder unopened and contact us with your order number and clear photos of the cylinder and shipping label.
Follow the cylinder label and current safety data sheet. Keep the cylinder upright, secured and in a cool, dry, well-ventilated area away from direct sunlight, excessive heat and ignition sources.
R448A is pressurized and can create serious exposure hazards. Handling and system service should be performed by a trained, appropriately certified technician using suitable tools and personal protective equipment. Never intentionally vent refrigerant.
Do not connect, use or attempt to repair a cylinder that appears damaged, punctured or leaking. Keep people away, avoid heat and ignition sources, and contact local emergency services if there is an immediate hazard.
For visible shipping damage, contact Velotrex when safe with your order number and clear photos. If tracking shows delivered but the shipment is missing, check the delivery photo, entrances, garage, front desk, mailroom and nearby properties before contacting us.
Email contact@velotrex.store with the order and tracking numbers, or call +1 (825) 360-9654.
Eligible orders ship free via FedEx and are generally processed within 24 hours. Estimated delivery is 2–5 business days within the contiguous United States. Returns are accepted within 14 days of delivery on unopened, unused cylinders with original packaging and labels intact. Opened or used refrigerant cylinders cannot be returned for safety and regulatory reasons.